Ukufika Okusha I-China Industrial Factory Laboratory Wall Ifakwe Udonga Olunembile Olujwayelekile Lokujwayelekile Kokuqukethwe Oksijini

Incazelo emfushane:

I-Dual Channel Oxygen Analyzer: Isihlaziyi esisodwa esinama-probes amabili singasindisa izindleko zokufaka futhi sithuthukise ukwethembeka.

Ibanga lokulinganisa komoyampilo liyi-10-30ku-100% i-oxygen.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Imvamisa ukuthambekela kumakhasimende, futhi kuyinhloso yethu enkulu ukuba singagcini nje ngokuba umhlinzeki onedumela elihle, onokwethenjelwa nothembekile, kodwa futhi sibe uzakwethu wamakhasimende ethu we-New Arrival China China Industrial Factory Laboratory Wall Mounted Accurate Normal Normal Oxygen Analyzer, Siyakwamukela okusha. kanye nabathengi abaphelelwe yisikhathi abavela kuyo yonke imikhakha yokuphila ukuze basibizele izinhlangano zezinkampani zesikhathi eside kanye nokufeza okuthile!
Ngokuvamile kuthambekele kumakhasimende, futhi kuyinhloso yethu enkulu ukuba singagcini nje ngokuba umhlinzeki ohlonishwa kakhulu, othembekile nothembekile, kodwa futhi sibe uzakwethu wamakhasimende ethuChina Lab Equipment, Izisetshenziswa zokuhlola, Ngokuthembela kwikhwalithi ephezulu kanye nokuthengiswa okuhle kakhulu kwangemva kokuthengisa, izixazululo zethu zithengisa kahle eMelika, eYurophu, eMpumalanga Ephakathi naseNingizimu Afrika.Siphinde saba yimboni eqokiwe ye-OEM yemikhiqizo eminingi edumile yomhlaba wonke nezisombululo.Siyakwamukela ukuxhumana nathi ukuze uthole ukuxoxisana nokubambisana okwengeziwe.

Ibanga lohlelo lokusebenza

I-Nernst N2032i-oxygen analyzeringaqapha ngokuqondile okuqukethwe komoyampilo egesini ephuma amanzi ngesikhathi noma ngemva kokushiswa kwamabhayela, izithando zomlilo, neziko.

Izici zohlelo lokusebenza

Ngemuva kokusebenzisa i-Nernsti-oxygen analyzer, abasebenzisi banganciphisa ukusetshenziswa kwamandla amaningi, balawule ukungcoliswa kwemvelo, baqinisekise ukukhiqizwa okuphephile futhi banwebe impilo yesevisi yezisetshenziswa, futhi babuyisele konke ukutshalwa kwezimali ngesikhathi esifushane.

Inqubo yokulawula ukushiswa kwe-peroxygen inganciphisa inani elikhulu lokusetshenziswa kwamandla.Ani-oxygen analyzeringasetshenziswa ukulawula isilinganiso sephethiloli emoyeni, ukuze uphethiloli ushiswe ngokugcwele ngenkathi ugwema inani elikhulu lokushisa elithathwa ukusha kwe-peroxygen nokunciphisa ukukhishwa kwe-COx, i-SOx, ne-NOx ekhiqizwa ukushisa kwe-peroxygen kunganciphisa ngokuphumelelayo. ukungcoliswa komoya kwezemvelo.Ngasikhathi sinye, ukulimala kwe-carbonic acid, i-sulfuric acid ne-nitric acid ekhiqizwa ukuxuba amagesi anjalo ayingozi namanzi kuya kumshini wamapayipi okubhayela nakho kungalawuleka.

Ukusetshenziswa kwei-oxygen analyzerngokuvamile ingasindisa u-8-10% wokusetshenziswa kwamandla.

Izici zobuchwepheshe

 Isilinganiso sama-probes amabili:I-analyzer eyodwa enama-probe amabili ingasindisa izindleko zokufaka futhi ithuthukise ukwethembeka.

Ukulawula okuphumayo kwamashaneli amaningi:I-analyzer inomphumela wamanje we-4-20mA kanye nesixhumi esibonakalayo sokuxhumana kwekhompyutha i-RS232 noma isixhumi esibonakalayo sokuxhumana kwenethiwekhi RS485

 Ibanga lokulinganisa:Ibanga lokulinganisa komoyampilo liyi-10-30ku-100% i-oxygen.

Ukulungiselelwa kwe-alamu:I-analyzer inokukhishwa kwe-alamu oku-1 okujwayelekile kanye nokuphumayo kwe-alamu oku-3 okuhlelekayo.

 Ukulinganisa okuzenzakalelayo:I-analyzer izoqapha ngokuzenzakalelayo amasistimu ahlukahlukene asebenzayo futhi ilinganise ngokuzenzakalelayo ukuze iqinisekise ukunemba kwe-analyzer ngesikhathi sokulinganisa.

Isistimu ehlakaniphile:I-analyzer ingaqedela imisebenzi yezilungiselelo ezahlukahlukene ngokuya ngezilungiselelo ezinqunywe kusengaphambili.

Bonisa umsebenzi wokuphumayo:I-analyzer inomsebenzi oqinile wokubonisa amapharamitha ahlukahlukene kanye nokukhipha okuqinile nomsebenzi wokulawula wamapharamitha ahlukahlukene.

Umsebenzi wokuphepha:Lapho isithando somlilo singasasebenzi, umsebenzisi angakwazi ukulawula ukucisha i-heater ye-probe ukuqinisekisa ukuphepha ngesikhathi sokusetshenziswa.

Ukufaka kulula futhi kulula:ukufakwa kwe-analyzer kulula kakhulu futhi kukhona ikhebula elikhethekile lokuxhuma ne-zirconia probe.

Imininingwane

Okokufaka

• I-zirconia oxygen probe eyodwa noma ezimbili noma izinzwa

• Inzwa eyodwa ye-zirconia nohlobo lwe-thermocouple olusizayo J, K, R noma S

• Isignali “Vula” yokushisa umlilo (othintana naye owomile)

• Hlanza iswishi yokugeleza komoya

Imiphumela

• Ukudluliselwa kwe-alamu okune okuhlelekayo

• Okubili okuhlukile okungu-4-20mA noma 0-20mA

• Imiphumela ye-SSR yokuhlanza nokulinganisa ukuhlola amavalvu e-solenoid yegesi

Ibanga Lemiphumela

Okukhiphayo okubili okungu-4~20mA DC

(Umthwalo omkhulu ngu-1000Ω)

• Ububanzi bokuqala bokuphumayo (kuyakhetheka)

Okukhiphayo komugqa 0~1% kuya ku-0~100% okuqukethwe komoyampilo

Okukhipha i-Logarithmic 0.1-20% okuqukethwe komoyampilo

Ukukhishwa kwe-Micro-oxygen 10-25kuye 10-1okuqukethwe kwe-oxygen

• Ibanga lesibili lokuphumayo (lingakhethwa kokulandelayo)

Ukuvutha

i-hypoxia

I-probe output voltage

i-carbon dioxide

Ukusebenza kahle

ukushisa kwe-flue

I-oxygen ye-Logarithmic

i-micro oxygen

Isibonisi Sepharamitha Yesibili

Noma yikuphi noma konke okulandelayo kungakhethwa ukuze kuboniswe kulayini ongezansi:

•Cela izinga lokushisa elingu-#1

•Cela izinga lokushisa elingu-#2

•Phequlula #1 EMF

•Phequlula #2 EMF

•Phenya #1 impedance

•Cela #2 impedance

•Oxygen % probe #2

•I-oxygen emaphakathi %

•Izinga lokushisa elisizayo

•Izinga lokushisa le-ambient

•Ambient RH %

•I-Carbon dioxide

•Izinto ezivuthayo

•Ukuntuleka komoyampilo

•Burner ukusebenza kahleI-condSecondary Parameter Display

Ukuhlanza uthuli kanye nokulinganiswa kwegesi okujwayelekile

I-analyzer inesiteshi esingu-1 sokususa uthuli kanye nesiteshi esingu-1 sokulinganisa igesi okujwayelekile noma amashaneli angu-2 okukhipha okujwayelekile kokulinganisa igesi, kanye neswishi ye-solenoid valve engasebenza ngokuzenzakalelayo noma ngesandla.

ary Ipharamitha Isibonisi

Ama-alamuIsibonisi sepharamitha

Kunama-alamu ajwayelekile angu-14 anemisebenzi ehlukene kanye nama-alamu angu-3 ahlelekayo.Ingasetshenziselwa izimpawu eziyisixwayiso njengezinga lokuqukethwe komoyampilo, amaphutha ophenyo kanye namaphutha okulinganisa.

UkunembaP

± 1% wokufundwa komoyampilo kwangempela ngokuphindaphinda okungu-0.5%.Isibonelo, ku-oxygen engu-2% ukunemba kungaba ±0.02% komoyampilo.

Ibanga Lenkomba Yendawo

1.0 x 10-30% kuya ku-100% Oxygen

0.01ppm kuya ku-10,000ppm - ishintsha ngokuzenzakalelayo ibe ifomethi yomchazi ngaphansi kuka-0.01ppm kanye nefomethi yephesenti ngaphezu kuka-10,000ppm (1%)

I-Serial/Network Interface

RS232

Idatha ye-RS485 MODBUSTM

Igesi eyinkomba

I-reference gas isebenzisa iphampu yokudlidliza ye-micro-motor

Amandla Ruireqements

85VAC kuya ku-240VAC 3A

Izinga Lokushisa Lokusebenza

Izinga Lokushisa Lokusebenza -25°C kuya ku-55°C

Umswakamo Ohlobene 5% ukuya ku-95% (okungafinyeleli)

Izinga Lokuvikeleka

IP65

IP54 enephampu yomoya eyinkomba yangaphakathi

Ubukhulu nesisindo

260mm W x 160mm H x 90mm D 3kgImvamisa kumakhasimende, futhi kuwumgomo wethu omkhulu ukuba singagcini nje ngokuba umhlinzeki ohlonishwa kakhulu, othembekile nothembekile, kodwa futhi sibe uzakwethu wamakhasimende ethu we-New Arrival China China Industrial Factory Laboratory Wall Mounted Accurate I-Oxygen Analyzer Yokuqukethwe Okujwayelekile, Samukela abathengi abasha nabaphelelwe yisikhathi abavela kuyo yonke imikhakha yokuphila ukuze basishayele ukuze bathole izinhlangano zesikhathi eside zezinkampani kanye nokufeza okufanayo!
Ukufika Okusha kwe-ChinaChina Lab Equipment, Izisetshenziswa zokuhlola, Ngokuthembela kwikhwalithi ephezulu kanye nokuthengiswa okuhle kakhulu kwangemva kokuthengisa, izixazululo zethu zithengisa kahle eMelika, eYurophu, eMpumalanga Ephakathi naseNingizimu Afrika.Siphinde saba yimboni eqokiwe ye-OEM yemikhiqizo eminingi edumile yomhlaba wonke nezisombululo.Siyakwamukela ukuxhumana nathi ukuze uthole ukuxoxisana nokubambisana okwengeziwe.


  • Okwedlule:
  • Olandelayo:

  • Imikhiqizo Ehlobene