I-Nernst N2032 oxygen analyzer

Incazelo emfushane:

I-Dual Channel Oxygen Analyzer: Isihlaziyi esisodwa esinama-probes amabili singasindisa izindleko zokufaka futhi sithuthukise ukwethembeka.

Ibanga lokulinganisa komoyampilo liyi-10-30ku-100% i-oxygen.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Ibanga lohlelo lokusebenza

I-Nernst N2032i-oxygen analyzeringaqapha ngokuqondile okuqukethwe komoyampilo egesini ephuma amanzi ngesikhathi noma ngemva kokushiswa kwamabhayela, izithando zomlilo, neziko.

Izici zohlelo lokusebenza

Ngemuva kokusebenzisa i-Nernsti-oxygen analyzer, abasebenzisi banganciphisa ukusetshenziswa kwamandla amaningi, balawule ukungcoliswa kwemvelo, baqinisekise ukukhiqizwa okuphephile futhi banwebe impilo yesevisi yezisetshenziswa, futhi babuyisele konke ukutshalwa kwezimali ngesikhathi esifushane.

Inqubo yokulawula ukushiswa kwe-peroxygen inganciphisa inani elikhulu lokusetshenziswa kwamandla. Ani-oxygen analyzeringasetshenziswa ukulawula isilinganiso sephethiloli emoyeni, ukuze uphethiloli ushiswe ngokugcwele ngenkathi ugwema inani elikhulu lokushisa elithathwa ukusha kwe-peroxygen nokunciphisa ukukhishwa kwe-COx, i-SOx, ne-NOx ekhiqizwa ukushisa kwe-peroxygen kunganciphisa ngokuphumelelayo. ukungcoliswa komoya kwezemvelo.Ngasikhathi sinye, ukulimala kwe-carbonic acid, i-sulfuric acid ne-nitric acid ekhiqizwa ukuxuba amagesi anjalo ayingozi namanzi kuya kumshini wamapayipi okubhayela nakho kungalawuleka.

Ukusetshenziswa kwei-oxygen analyzerngokuvamile ingasindisa u-8-10% wokusetshenziswa kwamandla.

Izici zobuchwepheshe

 Isilinganiso sama-probes amabili:I-analyzer eyodwa enama-probe amabili ingasindisa izindleko zokufaka futhi ithuthukise ukwethembeka.

Ukulawula okuphumayo kwamashaneli amaningi:I-analyzer inomphumela wamanje we-4-20mA kanye nesixhumi esibonakalayo sokuxhumana kwekhompyutha i-RS232 noma isixhumi esibonakalayo sokuxhumana kwenethiwekhi RS485

 Ibanga lokulinganisa:Ibanga lokulinganisa komoyampilo liyi-10-30ku-100% i-oxygen.

Ukulungiselelwa kwe-alamu:I-analyzer inokukhishwa kwe-alamu oku-1 okujwayelekile kanye nokuphumayo kwe-alamu oku-3 okuhlelekayo.

 Ukulinganisa okuzenzakalelayo:I-analyzer izoqapha ngokuzenzakalelayo amasistimu ahlukahlukene asebenzayo futhi ilinganise ngokuzenzakalelayo ukuze iqinisekise ukunemba kwe-analyzer ngesikhathi sokulinganisa.

Isistimu ehlakaniphile:I-analyzer ingaqedela imisebenzi yezilungiselelo ezahlukahlukene ngokuya ngezilungiselelo ezinqunywe kusengaphambili.

Bonisa umsebenzi wokuphumayo:I-analyzer inomsebenzi oqinile wokubonisa amapharamitha ahlukahlukene kanye nomsebenzi oqinile wokukhipha nokulawula wamapharamitha ahlukahlukene.

Umsebenzi wokuphepha:Lapho isithando somlilo singasasebenzi, umsebenzisi angakwazi ukulawula ukucisha i-heater ye-probe ukuze kuqinisekiswe ukuphepha ngesikhathi sokusetshenziswa.

Ukufaka kulula futhi kulula:ukufakwa kwe-analyzer kulula kakhulu futhi kukhona ikhebula elikhethekile lokuxhuma ne-zirconia probe.

Imininingwane

Okokufaka

• I-zirconia oxygen probe eyodwa noma ezimbili noma izinzwa

• Inzwa eyodwa ye-zirconia nohlobo lwe-thermocouple olusizayo J, K, R noma S

• Isignali “Vula” yokushisa umlilo (othintana naye owomile)

• Hlanza iswishi yokugeleza komoya

Imiphumela

• Ukudluliselwa kwe-alamu okune okuhlelekayo

• Okubili okuhlukile okungu-4-20mA noma 0-20mA

• Imiphumela ye-SSR yokuhlanza nokulinganisa ukuhlola amavalvu e-solenoid yegesi

Ibanga Lemiphumela

Okukhiphayo okubili okungu-4~20mA DC

(Umthwalo omkhulu ngu-1000Ω)

• Ububanzi bokuqala bokuphumayo (kuyakhetheka)

Okukhiphayo komugqa 0~1% kuya ku-0~100% okuqukethwe komoyampilo

Okukhipha i-Logarithmic 0.1-20% okuqukethwe komoyampilo

Ukukhishwa kwe-Micro-oxygen 10-25kuye 10-1okuqukethwe kwe-oxygen

• Ibanga lesibili lokuphumayo (lingakhethwa kokulandelayo)

Ukuvutha

i-hypoxia

I-probe output voltage

i-carbon dioxide

Ukusebenza kahle

ukushisa kwe-flue

I-oxygen ye-Logarithmic

i-micro oxygen

Isibonisi Sepharamitha Yesibili

Noma yikuphi noma konke okulandelayo kungakhethwa ukuze kuboniswe kulayini ongezansi:

•Cela izinga lokushisa elingu-#1

•Cela izinga lokushisa elingu-#2

•Phequlula #1 EMF

•Phequlula #2 EMF

•Phenya #1 impedance

•Cela #2 impedance

•Oxygen % probe #2

•I-oxygen emaphakathi %

•Izinga lokushisa elisizayo

•Izinga lokushisa le-ambient

•Ambient RH %

•I-Carbon dioxide

•Izinto ezivuthayo

•Ukuntuleka komoyampilo

•Burner ukusebenza kahleI-condSecondary Parameter Display

Ukuhlanza uthuli kanye nokulinganiswa kwegesi okujwayelekile

I-analyzer inesiteshi esingu-1 sokususa uthuli kanye nesiteshi esingu-1 sokulinganisa igesi okujwayelekile noma amashaneli angu-2 okukhipha ukulinganisa kwegesi okujwayelekile, kanye neswishi ye-solenoid valve engasebenza ngokuzenzakalelayo noma ngesandla.

ary Ipharamitha Isibonisi

Ama-alamuIsibonisi sepharamitha

Kunama-alamu ajwayelekile angu-14 anemisebenzi ehlukene kanye nama-alamu angu-3 ahlelekayo. Ingasetshenziselwa izimpawu eziyisixwayiso njengezinga lokuqukethwe komoyampilo, amaphutha ophenyo kanye namaphutha okulinganisa.

UkunembaP

± 1% wokufundwa komoya-mpilo kwangempela ngokuphindaphinda okungu-0.5%. Isibonelo, ku-2% umoya-mpilo ukunemba kungaba ± 0.02% komoyampilo.

Ibanga Lenkomba Yendawo

1.0 x 10-30% kuya ku-100% Oxygen

0.01ppm kuya ku-10,000ppm - ishintsha ngokuzenzakalelayo ibe ifomethi yomchazi ngaphansi kuka-0.01ppm kanye nefomethi yephesenti ngaphezu kuka-10,000ppm (1%)

I-Serial/Network Interface

RS232

Idatha ye-RS485 MODBUSTM

I-reference gas

I-reference gas isebenzisa iphampu yokudlidliza ye-micro-motor

Amandla Ruireqements

85VAC kuya ku-240VAC 3A

Izinga Lokushisa Lokusebenza

Izinga Lokushisa Lokusebenza -25°C kuya ku-55°C

Umswakamo Ohlobene 5% ukuya ku-95% (okungafinyeleli)

Izinga Lokuvikeleka

IP65

IP54 enephampu yomoya eyinkomba yangaphakathi

Ubukhulu nesisindo

260mm W x 160mm H x 90mm D 3kg


  • Okwedlule:
  • Olandelayo:

  • Imikhiqizo Ehlobene