Nernst N2032 Oxygen Analyzer

Incazelo emfushane:

I-Dual Channel Oxygen Analyzer: Ukuhlaziywa okukodwa okunama-probus amabili kungagcina izindleko zokufaka futhi kuthuthukise ukuthembeka.

Uhla lokulinganisa lwe-oxygen luyi-10-30kuya ku-100% oksijini.


Imininingwane Yomkhiqizo

Amathegi Omkhiqizo

Ibanga lesicelo

IN nanrst N2032Ukuhlaziywa komoya-mpilo

Izici zohlelo lokusebenza

Ngemuva kokusebenzisa iNernstUkuhlaziywa komoya-mpilo, abasebenzisi banganciphisa ukusetshenziswa okuningi kwamandla, balawule ukungcoliswa kwemvelo, baqinisekise ukukhiqizwa okuphephile futhi bandise impilo yensiza yemishini, bese babuyisa konke ukutshalwa kwezimali ngesikhathi esifushane.

Inqubo yokulawula ukuhlanganiswa kwe-peroxygen inganciphisa inani elikhulu lokusetshenziswa kwamandla. AUkuhlaziywa komoya-mpiloingahle isetshenziselwe ukulawula isilinganiso samafutha emoyeni, ukuze uphethiloli ushiswa ngokugcwele ngenkathi ugwema inani elikhulu lokushisa elisuswa nge-peroxygen, ukulimala kwe-Carbic, i-nitric acid ekhiqizwe ngokuxutshwa kwamagesi alimazayo anamanzi Imishini yepayipi nayo ingalawulwa.

Ukusetshenziswa kweUkuhlaziywa komoya-mpilongokuvamile ingagcina i-8-10% yokusetshenziswa kwamandla.

Izici Zobuchwepheshe

 Amabili aphenya:Ukuhlaziywa okukodwa okunama-probus amabili kungagcina izindleko zokufaka futhi kuthuthukise ukuthembeka.

Ukulawulwa kokukhipha iziteshi eziningi:I-analyzer ine-4 kuya ku-4-20mA yamanje yokukhipha kanye ne-computer yokuxhumana i-RS232 noma isikhombimsebenzisi senethiwekhi Rs485

 Uhla lokulinganisa:Uhla lokulinganisa lwe-oxygen luyi-10-30kuya ku-100% oksijini.

Ukuhlelwa kwe-alamu:I-analyzer inokukhishwa okungu-1 okujwayelekile okuphumayo kanye nemiphumela emi-3 ye-alamu ehlelekile.

 Ukulinganisa okuzenzakalelayo:I-analyzer izobheka ngokuzenzakalelayo izinhlelo ezahlukahlukene zokusebenza futhi zilinganise ngokuzenzakalelayo ukuze kuqinisekiswe ukunemba kwe-analyzer ngesikhathi sokulinganisa.

Uhlelo Oluqondayo:I-analyzer ingaqedela imisebenzi yezilungiselelo ezahlukahlukene ngokuya ngezilungiselelo ezinqunywe kusengaphambili.

Khombisa umsebenzi wokukhipha:I-analyzer inomsebenzi oqinile wokubonisa amapharamitha ahlukahlukene kanye nokukhipha okuqinile nokulawula umsebenzi wamapharamitha ahlukahlukene.

Umsebenzi Wokuphepha:Lapho isithando somlilo siphelelwe yisikhathi, umsebenzisi angakwazi ukulawula ukucisha i-heater of the probe ukuqinisekisa ukuphepha ngesikhathi sokusebenzisa.

Ukufaka kulula futhi kulula:Ukufakwa kwe-analyzer kulula kakhulu futhi kunentambo ekhethekile yokuxhuma ne-zirconia probe.

Ukucacisa

Okokufaka

• Izingcweti zomoya owodwa noma ezimbili noma ezimbili ze-zirconia

• inzwa eyodwa ye-zirconia nohlobo lwe-thermocouple olusizayo J, k, R noma s

• I-Burner "ku" Signal (Oxhumana Nayo Emile)

• Hlanza i-air flow switch

Okuphumayo

• Ukudluliselwa kwe-alamu ezine ezihlelekile

• Ababili bahlukaniswe ngo-4-20m noma 0-20ma

• Imiphumela ye-SSR yokuhlanza nokulinganisa hlola igesi Solenoid valves

Uhla lokuphuma

Imigqa emibili eqondile 4 ~ 20ma DC okukhipha

(Umthwalo omkhulu 1000ω)

• Uhla lokuphuma lokuqala (ngokuzithandela)

Ukukhishwa komugqa 0 ~ 1% kuya ku-0 ~ 100% Oxygen okuqukethwe

Ukukhishwa kwe-Logarithmic 0.1-20% Oxygen Okuqukethwe

Ukukhishwa kwe-Micro-Oxygen 10-25kuya ku-10-1Okuqukethwe komoya-mpilo

• Uhla lwesibili lokukhipha (lungakhethwa kusuka kokulandelayo)

Ukuvulayo

i-hypoxia

I-Profe Output Voltage

I-Carbon Dioxide

Ikhono lokwenza

I-Flue lokushisa

I-logarithmic okygen

umoya-mpilo omncane

Isibonisi sepharamitha yesibili

Noma yikuphi noma konke lokhu okulandelayo kungakhethwa ukuze kuboniswe emugqeni ophansi:

• Probe # 1 lokushisa

• Profe # 2 lokushisa

• Probe # 1 Emf

• Probe # 2 EMF

• Probe # 1 Ukuvimbela

• Probe # 2 Ukuvimbela

• I-OXYGEN% Probe # 2

• Isilinganiso somoya-mpilo%

• Izinga lokushisa elisizayo

• Ukushisa okukhona

• I-Ambient Rh%

• I-Carbon Dioxide

• Izimbotshana

• Ukuntuleka komoya-mpilo

• ukusebenza kahleI-condecondary parameter Display

Ukuhlanza Uthuli kanye Nokulinganisa Kwegesi Ejwayelekile

I-analyzer inesiteshi esingu-1 sokususwa kothuli kanye nesiteshi esingu-1 sokulinganisa amagesi ajwayelekile noma iziteshi ezi-2 zokudluliselwa okujwayelekile kwegesi ukudluliselwa, kanye nokushintshwa kwe-solenoid valve okungasebenza ngokuzenzakalelayo noma ngesandla.

I-Ary Parameter Display

AmakhuliseIsibonisi sepharamitha

Kunama-alamu ajwayelekile ayi-14 anemisebenzi ehlukene nama-alamu ama-3 ahlelekile. Ingasetshenziselwa izimpawu zokuxwayisa ezifana nezinga lokuqukethwe komoya-mpilo, amaphutha wokuphenya kanye namaphutha wokulinganisa.

Ukuqonda nqoP

± 1% yokufundwa kwangempela komoya-mpilo ngokuphindaphindwa kwe-0.5%. Isibonelo, ngo-2% oksijini ukunemba kungaba ± 0,02% oksijini.

Uhla lwenkomba yendawo

I-1.0 x 10-30% kuya ku-100% umoya-mpilo

I-0.01ppm kuya ku-10,000ppm - okuzenzakalelayo ngokuzenzakalelayo kwefomethi ebonakalayo ngaphansi kwe-0.01ppp kanye nefomethi yamaphesenti ngaphezulu kwe-10,000ppm (1%)

Isikhombimsebenzisi esibonakalayo se-serial / senethiwekhi

I-RS232

I-Rs485 ModbusTM

Ukubhekisisa igesi

I-Preferes Gas admatic pump micro-motor vibration pump

Amandla Ruieqements

I-85Vac kuya ku-240vac 3a

Ukushisa okusebenzayo

Ukushisa okusebenzayo -25 ° C kuya ku-55 ° C

Umswakama ohlobene 5% kuya ku-95% (okungaphenduli)

Degree of ukuvikelwa

IP65

I-IP54 ngereferensi yangaphakathi yomoya

Ubukhulu nesisindo

260mm W x 160mm h x 90mm d 3kg